Several members failed within minutesA power-on-hour limit in the firmware. Stop; do not update the failed ones.Do not delay
Drive shows 0 GBThe failed state of Dell's LT-series at 40,000 hours, and of other controller faults.Do not delay
Failed after a power eventController or its firmware. Imaged at controller level where the model allows.Everyday job
Predictive failure with wear at 100 per centWrite endurance spent. Image it now; it reads until it does not.Do not delay
Consumer SSD dropped out of a set870 EVO and its relatives bring consumer faults to server jobs.Everyday job
SAS SSD locked after a controller swapA SED. Find the key.Do not delay
Packing it and posting it: power the server or shelf down, write the slot number on each drive with a marker before it comes out of its carrier, and keep it in the carrier. Send every member from the set where the set is the job, or the one failed member where the set is healthy and you want it imaged for the rebuild. Each drive travels in an anti-static bag inside its own padding, in a box with nothing able to move. Send the controller only if we ask for it. Insure the parcel for what the data is worth rather than the price of the drives, and use a tracked service. The posting address is not printed anywhere on this site; it arrives by email in reply to the form, with a booking sheet to print; the sheet inside the parcel is what matches it to your enquiry when it is opened. Or hand the sealed parcel in at the nearest of
ten drop-off points, your name on the outside and the sheet inside; say where you are on the form and it comes by email. We pay the postage home either way. The whole of it is written up on the
guide to packing and posting.