Taking work now — the first look is freeServer and RAID drives posted in from anywhere in the UK, or handed in at ten drop-off pointsQuicker still, give us a ring:0800 6890668
RDDRAID Drive Data Recovery 0800 6890668 Price my job
RDD / Families and hosts / Enterprise SSD members

Micron 5300 · 7450 · Samsung PM893 · PM9A3 · PM1643 · Intel D3-S4510 · P4510 · Kioxia PM6 · CM6 · WD SN840

Enterprise SSD recovery. Fast until the controller stops answering, and then all at once.

Five makers supply nearly every solid-state member: Micron's 5300, 5400 and 7450, Samsung's PM893, PM9A3 and PM1643, Intel and now Solidigm's D3-S4510 and P4510, Kioxia's PM6, CM6 and CD6, and SanDisk and WD's SN640 and SN840, under their own names and under HPE's, Dell's and Lenovo's. They fail at the controller and in the firmware, sometimes on a schedule, and they spend their endurance together: a write-intensive set that fitted six drives on one day reports six wear indicators at 100 per cent in one month. Cheap sets built from consumer drives bring consumer faults, the Samsung 870 EVO's early-2021 batches among them. One SSD member imaged is £300 + VAT after the free look, fixed in writing, 3–4 days at the bench; some firmware failures leave nothing readable, and the free look says which before any charge.

Free first lookOne fixed figure in writingNo data, no bill on most jobsReturn postage paid

Rather talk it through? An engineer answers the bench line
0800 6890668

Power down. Label every slot before a drive comes out. Do not rebuild while a second drive is flagged. Do not clear or import a foreign configuration. Do not initialise, reformat or PSID-revert anything. A rebuild reads every sector of every surviving member, and on a set whose drives were bought together it is where the second failure is found. Nothing on the drives gets worse while the server is off.

Models we see, family by family.

Which kind of drive is it →
Family Model strings Interface, capacity and notes
MicronMTFDDAK…TDS (5300), MTFDDAK…TGA (5400), MTFDKCC…TFR (7450)SATA and NVMe · vSAN nodes
SamsungMZ7L3… (PM893), MZQL2… (PM9A3), MZILT… (PM1643)SATA, NVMe, SAS
Intel / SolidigmSSDSC2KB… (D3-S4510), SSDPE2KX… (P4510)SATA and NVMe
KioxiaKPM6… (PM6), KCM6… (CM6), KCD6… (CD6)SAS and NVMe
SanDisk / WDSN640, SN840, and the LT-series under Dell's labelNVMe and SAS

What tends to go wrong on an enterprise SSD.

Firmware clocksHPE's and Dell's SAS SSD failures at 32,768 and 40,000 hours were SanDisk-built drives; HPE's NVMe line at 4,700 hours another. Whole batches fail together, and some leave nothing to read.
Endurance spent togetherA set of write-intensive drives fitted together spends its rated writes together. The first wear indicator at 100 per cent is a set of drives a few weeks apart.
Consumer drives in server setsSamsung 870 EVO drives from January and February 2021 batches developed uncorrectable errors, and turn up in RAID sets built to a price. They bring consumer recovery odds to a server job.
What the bench can doControllers that answer are imaged at once. Controllers that do not are worked at chip level where the model allows, and the free look is honest about the ones that cannot be.

Enterprise SSD members symptoms, and how long each gives you.

Not listed? Describe it on the form →
Packing it and posting it: power the server or shelf down, write the slot number on each drive with a marker before it comes out of its carrier, and keep it in the carrier. Send every member from the set where the set is the job, or the one failed member where the set is healthy and you want it imaged for the rebuild. Each drive travels in an anti-static bag inside its own padding, in a box with nothing able to move. Send the controller only if we ask for it. Insure the parcel for what the data is worth rather than the price of the drives, and use a tracked service. The posting address is not printed anywhere on this site; it arrives by email in reply to the form, with a booking sheet to print; the sheet inside the parcel is what matches it to your enquiry when it is opened. Or hand the sealed parcel in at the nearest of ten drop-off points, your name on the outside and the sheet inside; say where you are on the form and it comes by email. We pay the postage home either way. The whole of it is written up on the guide to packing and posting.

What the message means on an enterprise SSD.

Describe yours to us →
What you see The usual reason Where that leaves you
Several failed within minutesA firmware clockStop; check the survivors' hours; assessed at controller level
Shows 0 GBController haltedAssessed at controller level; model permitting
Predictive failure; wear at 100 per centEndurance spentImage now
Failed after a power eventMapping table inconsistentController-level work where supported

From the parcel arriving to your files going back.

Work we have closed →
01

Logged the day it lands, and the first look costs nothing Free

A case number goes on the parcel and a number on every drive the day it is opened, matched to the slot you wrote on it. An engineer settles what has actually happened before anything spins: the interface, the sector format, the firmware, the security state, and what the controller was saying when it stopped. Back to you come two things together: a straight note of what is liftable and what is not, plus one figure, fixed and written down. Accept it, or decline and owe us nothing.

Nothing to pay for lookingA single figure, put in writingNo rebuilds, no imports, no resets
02

The drive on its own bench

A member drive is read on the equipment its interface needs: a SAS imager for SAS and NL-SAS, a SATA imager for enterprise SATA, a terminated SCSI or Fibre Channel controller for the legacy drives, a PCIe adaptor for NVMe. It is never put back in a server, and never in a controller that will try to rebuild. Drives that answer at full speed are imaged; drives with weak or failed heads go to the clean bench, where matched donors are fitted and the service area repaired before a sector is read.

Read at its native interfaceFailing heads to the clean bench
03

Imaged once, at its native sector size

Every drive is imaged sector by sector, head by head where it needs it, with the bad areas last. Drives with 520- or 528-byte sectors are imaged as they are and the extra bytes stripped from the image, never the drive. Self-encrypting drives are unlocked on the imager with the key you supply. From then on the originals are not touched again.

Head by head, weak areas lastNative sector size preserved
04

The image, and the set

Where the set is healthy and one member was the job, the image goes back to you on a fresh drive, sector-identical, ready to rebuild from. Where the set is the job, every member is imaged and the array reassembled in software from the images: order, chunk size, parity rotation and the reshape point read from the drives' own metadata, the file system repaired on the virtual volume, never on the originals. The array work is covered in full on our RAID array site, and it happens on the same bench.

One member: a sector-identical image on fresh mediaA set: reassembled in software from the images
05

You see the file list before you pay

What was recovered is listed for you first, and only then does a bill exist. Approve the list and it is invoiced; turn it down and it is not — and where nothing has come back, most jobs carry no charge at all. Recovered data travels home on fresh media bought in for your job, with the postage at our end. Your case is not closed until you have opened the files on a machine of your own.

No charge until you accept the figureFresh media, supplied with the job3–4 days at the bench

From the bench

  • An SSD that reads should be imaged now. Controllers fail without warning and without a second chance.
  • Do not update firmware on failed drives. The fix prevents the failure; it does not undo it.
  • The free look says what is possible, and on some firmware failures the honest answer is nothing. It costs nothing to hear it.

What helps, and what harms.

Do this much first

  • Stop, and read the power-on hours on every survivor
  • Label the slots and send the failed drives
  • Tell us the model strings and firmware revisions
  • Send the survivors too if the set has failed

What sets us back

  • Updating firmware on failed drives
  • Re-adding a failed drive to see
  • Rebuilding onto survivors on the same clock
  • Assuming a drive that reads today will read tomorrow

Questions answered before you commit.

Can you recover an enterprise SSD that failed in a RAID?

Often. If the controller answers it is imaged at once; if not, it is worked at controller or chip level where the model allows. The free look says which, at no charge.

All my SSDs are showing wear at 100 per cent. What now?

Image the flagged ones now and plan for the rest. They were fitted together and they wear together.

What does it cost?

£300 + VAT for one drive after the free look, fixed in writing; sets of two to four from £500 + VAT.

How long does it take?

3–4 days at the bench for one drive.

Nothing gets worse while it is powered down.

Looking at it is free. Back comes a list of what opened and what did not, together with a single price to finish, set down in writing while you are still free to say no. On most jobs an invoice only follows the data. Until that list reaches you, leave the server off and the drives in their slots.

0800 6890668