Taking work now — the first look is freeServer and RAID drives posted in from anywhere in the UK, or handed in at ten drop-off pointsQuicker still, give us a ring:0800 6890668
RDDRAID Drive Data Recovery 0800 6890668 Price my job
RDD / Families and hosts / Lenovo / IBM-branded drives

ThinkSystem SR630 · SR650 · System x3650 · xSeries 346 · FRU · ServeRAID · Storwize

Lenovo / IBM-branded drives drive recovery. IBM's servers became Lenovo's, and the drives kept their FRU numbers.

Lenovo's ThinkSystem and the System x line it bought from IBM in 2014, and the IBM xSeries before that, carry drives with a FRU or option part number over the maker's label and Lenovo or IBM firmware on top: Seagate, HGST and Toshiba mechanics in Lenovo carriers, on ServeRAID and later Broadcom-based controllers with their own dialect of degraded, failed and foreign. On the bench they are the drives underneath. One Lenovo or IBM-branded member imaged is £300 + VAT after the free look, fixed in writing, 3–4 days at the bench.

Free first lookOne fixed figure in writingNo data, no bill on most jobsReturn postage paid

Rather talk it through? An engineer answers the bench line
0800 6890668

Power down. Label every slot before a drive comes out. Do not rebuild while a second drive is flagged. Do not clear or import a foreign configuration. Do not initialise, reformat or PSID-revert anything. A rebuild reads every sector of every surviving member, and on a set whose drives were bought together it is where the second failure is found. Nothing on the drives gets worse while the server is off.

Models we see, family by family.

Which kind of drive is it →
Family Model strings Interface, capacity and notes
ThinkSystemLenovo-labelled ST…MM, HUC…, AL14…, MG…SAS 12Gb/s · Gen1 and Gen2
System xIBM and Lenovo-labelled 10K and 15K SASM4 and M5 · ServeRAID M5210
xSeries (legacy)IBM DDYS, IC35, HUS103 SCSIUltra320 · ServeRAID 6i and 7k
Storwize and DSIBM-labelled NL-SAS at 520 bytesImaged at native size

What tends to go wrong on a Lenovo drive.

ServeRAIDIBM's and Lenovo's controllers are LSI and Broadcom underneath, and report foreign configurations the same way. Do not clear them.
Storwize drivesIBM's Storwize and DS arrays format their drives with 520-byte sectors. A standard host sees 0 GB; the bench images at native size.

Lenovo / IBM-branded drives symptoms, and how long each gives you.

Not listed? Describe it on the form →
Packing it and posting it: power the server or shelf down, write the slot number on each drive with a marker before it comes out of its carrier, and keep it in the carrier. Send every member from the set where the set is the job, or the one failed member where the set is healthy and you want it imaged for the rebuild. Each drive travels in an anti-static bag inside its own padding, in a box with nothing able to move. Send the controller only if we ask for it. Insure the parcel for what the data is worth rather than the price of the drives, and use a tracked service. The posting address is not printed anywhere on this site; it arrives by email in reply to the form, with a booking sheet to print; the sheet inside the parcel is what matches it to your enquiry when it is opened. Or hand the sealed parcel in at the nearest of ten drop-off points, your name on the outside and the sheet inside; say where you are on the form and it comes by email. We pay the postage home either way. The whole of it is written up on the guide to packing and posting.

What the message means on a Lenovo drive.

Describe yours to us →
What you see The usual reason Where that leaves you
Predictive failureThresholds crossed; still readsReplace on a healthy set; image first on a degraded one
Failed by the controller; spinsAnswered one read too slowlyUsually reads on the bench; image it
ClickingFailed headsPower down; matched donor in clean air
Rebuild stalled on this driveUnrecoverable read errorsImaged with weak areas last; set rebuilt from images

From the parcel arriving to your files going back.

Work we have closed →
01

Logged the day it lands, and the first look costs nothing Free

A case number goes on the parcel and a number on every drive the day it is opened, matched to the slot you wrote on it. An engineer settles what has actually happened before anything spins: the interface, the sector format, the firmware, the security state, and what the controller was saying when it stopped. Back to you come two things together: a straight note of what is liftable and what is not, plus one figure, fixed and written down. Accept it, or decline and owe us nothing.

Nothing to pay for lookingA single figure, put in writingNo rebuilds, no imports, no resets
02

The drive on its own bench

A member drive is read on the equipment its interface needs: a SAS imager for SAS and NL-SAS, a SATA imager for enterprise SATA, a terminated SCSI or Fibre Channel controller for the legacy drives, a PCIe adaptor for NVMe. It is never put back in a server, and never in a controller that will try to rebuild. Drives that answer at full speed are imaged; drives with weak or failed heads go to the clean bench, where matched donors are fitted and the service area repaired before a sector is read.

Read at its native interfaceFailing heads to the clean bench
03

Imaged once, at its native sector size

Every drive is imaged sector by sector, head by head where it needs it, with the bad areas last. Drives with 520- or 528-byte sectors are imaged as they are and the extra bytes stripped from the image, never the drive. Self-encrypting drives are unlocked on the imager with the key you supply. From then on the originals are not touched again.

Head by head, weak areas lastNative sector size preserved
04

The image, and the set

Where the set is healthy and one member was the job, the image goes back to you on a fresh drive, sector-identical, ready to rebuild from. Where the set is the job, every member is imaged and the array reassembled in software from the images: order, chunk size, parity rotation and the reshape point read from the drives' own metadata, the file system repaired on the virtual volume, never on the originals. The array work is covered in full on our RAID array site, and it happens on the same bench.

One member: a sector-identical image on fresh mediaA set: reassembled in software from the images
05

You see the file list before you pay

What was recovered is listed for you first, and only then does a bill exist. Approve the list and it is invoiced; turn it down and it is not — and where nothing has come back, most jobs carry no charge at all. Recovered data travels home on fresh media bought in for your job, with the postage at our end. Your case is not closed until you have opened the files on a machine of your own.

No charge until you accept the figureFresh media, supplied with the job3–4 days at the bench

From the bench

  • Failed by the controller is not failed. Enterprise firmware reports a bad sector in seconds; the controller drops the drive; the drive reads on a bench that waits.
  • Send it in its carrier with the slot written on it, and the controller's log if you can export one.
  • Drives bought together fail together. When one goes, the survivors are on notice, and the rebuild is where it shows.

What helps, and what harms.

Do this much first

  • Power down and label the slot
  • Send the drive in its carrier
  • Export the controller log
  • Tell us the model string and the firmware revision

What sets us back

  • Rebuilding with a second drive flagged
  • Putting the drive back in to see
  • Running a long SMART test on a weak drive
  • Handing the failed drive to the warranty courier first

Questions answered before you commit.

Does Lenovo recover data from ThinkSystem drives?

Not as a service we could find. Its support returns the failed drive unless a retention option is bought; the recovery is done here.

Do I send one drive or the set?

One drive where the set is healthy and you want it imaged for the rebuild; every member, labelled by slot, where a second drive is flagged or the set has failed.

What does it cost?

£300 + VAT for one drive after the free look; a set of two to four is £500 + VAT upwards, fixed in writing.

How long does it take?

3–4 days at the bench for one drive; 5–10 days at the bench for a set.

Nothing gets worse while it is powered down.

Looking at it is free. Back comes a list of what opened and what did not, together with a single price to finish, set down in writing while you are still free to say no. On most jobs an invoice only follows the data. Until that list reaches you, leave the server off and the drives in their slots.